Index
All boiler fault codes
Every code we cover, grouped by manufacturer. Not sure of the brand? Try the "any brand" pages at the bottom.
Vaillant
- F.22Low water pressure
- F.28Boiler failed to light on start-up
- F.29Flame went out and wouldn't relight
- F.75Pump didn't detect a pressure rise
- F.83Temperature not rising as expected
- F.20Overheat safety cut-out
- F.23Water not circulating well
- F.24Temperature rising too fast
- F.25Flue gas temperature too high
- F.27Flame detected when there shouldn't be one
- F.32Fan fault
- F.54No gas pressure on start-up
- F.61Gas valve control fault
- F.62Gas valve slow to shut off
- F.72Temperature sensor mismatch
- F.00Flow temperature sensor disconnected
- F.01Return temperature sensor disconnected
- F.02Hot water outlet sensor disconnected
- F.03Cylinder temperature sensor disconnected
- F.10Flow temperature sensor short circuit
- F.11Return temperature sensor short circuit
- F.12Hot water outlet sensor short circuit
- F.13Cylinder or warm-start sensor short circuit
- F.26Gas valve not working
- F.42Coding resistor fault
- F.49eBUS voltage too low
- F.52Mass flow sensor not connected
- F.53Unexpected gas flow through the valve
- F.55Carbon monoxide sensor fault
- F.56Carbon monoxide limit exceeded
- F.57Fault in the measuring programme
- F.63EEPROM memory fault
- F.64Electronics or safety sensor fault
- F.65Electronics overheating
- F.67Implausible flame signal
- F.68Unstable flame signal
- F.70Invalid device number
- F.71Flow sensor reading implausible
- F.73Pressure sensor signal too low
- F.74Pressure sensor signal too high
- F.77Flue flap or condensate pump fault
- F.78External control wiring fault
- F.80Store inlet sensor fault
- F.81Cylinder charging pump fault
- F.82Cylinder anode fault
- F.84Temperature difference implausible
- F.85Temperature sensors fitted wrongly
- F.90Store communication fault
- F.91Store sensor fault
- F.92Wrong gas type
- F.93Combustion out of range
- F.94Pressure sensors implausible
Worcester Bosch
- EA 227No flame detected after ignition
- EA 229Flame lost while running
- A21Lost signal from wireless thermostat
- E9 224Overheat safety cut-out
- C6Fan fault
- A1 281Pump stuck or running dry
- F7Flame detected when off
- A7Hot water sensor fault
- A8Controls communication fault
- B1Code plug not detected
- B7 257Internal control board error
- C1 264Fan stopped during operation
- C4 273Fan or airflow check fault
- C7 214Fan not running
- CCOutdoor sensor fault
- D1 240Return sensor fault
- D3External temperature limiter
- D4 271Temperature rising too fast
- D5Condensate pump failure
- E2 222Flow sensor fault
- E5 218Flow temperature too high
- E9 219Heat exchanger overheated
- EA 234Gas valve coil disconnected
- EA 261Ignition timing error
- EA 338Too many short burner starts
- EF 349Flow and return temperature gap too big
- F0 237Internal error
- FA 306Flame detected after shut-off
- FA 364Gas valve leak test failed (EV2)
- FB 365Gas valve leak test failed (EV1)
- FD 231Power interrupted
- 9A 362Wrong control module fitted
- 9U 233Control module or code plug fault
- H11Hot water sensor maintenance warning
- H13Service due
- 1017Water pressure too low
- 2971System pressure too low
- 2970Pressure dropping too fast
- 1065Pressure sensor fault
- 2927Flame failed during operation
- 2948No flame signal
- 2964Heat exchanger flow too low
- 2965Flow temperature too high
- 2966Flow temperature rising too fast
- 1010Controls bus cable fault
- 1021Hot water sensor fault
- 1037Outside sensor fault
- 1073Flow sensor short circuit
- 2924Gas valve feedback fault
Ideal
- F1Low water pressure
- F2Flame loss
- F3Fan fault
- F4Flow temperature sensor fault
- L2Ignition lockout
- L1Low water flow
- L5Return problem
- FDNo water flow
- F5Return thermistor fault
- F6Outside sensor fault
- F7Low mains voltage
- F9Unconfigured circuit board
- FUFlow and return 50°C apart
- FAFlow and return reversed
- FLFlame loss
- L4Flow thermistor fault
- L6Flame detection fault
- L9Return thermistor fault or overheat
- LABoiler overheated
- LFFailed to ignite
- LCToo many resets
- C0Boiler chip card activation fault
- C2Boiler chip card fault
- H3Hot water thermistor fault
Baxi
- E119Low water pressure
- E133Gas supply interrupted or ignition failed
- E118Water pressure too low
- E110Overheat safety thermostat
- E125Circulation fault
- E160Fan fault
- E168General lockout
- E28Flue fault
- E20Heating temperature sensor fault
- E09Gas valve cable fault
- E15Gas valve command fault
- E40Return sensor fault
- E50Hot water sensor fault
- E53Flue obstruction
- E55Calibration needed
- E78Water pressure sensor fault
- E83Communication fault
- E109Pre-circulation fault
- E128Flame failure
- E129Flame loss during calibration
- E130Flue thermostat tripped
- E134Gas valve open with no gas
- E135Gas supply interrupted
- E154Flow and return sensor test failed
- E193Pre-circulation fault
- E270Circulation fault
- E321Hot water sensor fault
- E384False flame signal
- E.02.07Low system pressure
- H.02.06Low pressure warning
- E.04.10Failure to light
- E.01.04Flame lost five times
- H.03.02No flame detected
- E.01.12Reset required
- E.01.17No circulation
- E.01.20Flue gas too hot
- E.02.00Reset in progress
- E.04.03Critical flow temperature
- E.04.12False flame signal
- E.04.13Fan blocked
- H.01.00Gas valve communication lost
Glow-worm
- F.22Low water pressure
- F.28Failed to light on start-up
- F.29Flame lost during operation
- F.75Pressure sensor or pump fault
- F.20Overheat safety cut-out
- F.23Water not circulating well
- F.24Temperature rising too fast
- F.26Gas valve fault
- F.27Flame detected when there shouldn't be one
- F.32Fan fault
- F.49eBUS voltage fault
- F.54No gas pressure on start-up
- F.61Gas valve control fault
- F.62Gas valve slow to shut off
- F.63Memory fault on the circuit board
- F.64Electronics or sensor fault
- F.65Electronics overheating
- F.67Implausible flame signal
- F.68Unstable flame signal
- F.70Software or device number mismatch
- F.72Temperature sensor mismatch
- F.73Pressure sensor signal too low
- F.74Pressure sensor signal too high
- F.77Condensate pump fault
- F.83Temperature not rising as expected
- F.84Temperature sensors disagree
- F.85Underfloor or sensor contact fault
- F1Ignition fault
- F3Fan not reaching ignition speed
- F4Ignition fault
- F5Overheating
- F6Heating flow thermistor fault
- F9Pressure sensor, flow filter or pump fault
- F10Heating return thermistor fault
- F11Main board connection fault
- F13Circuit board memory fault
- F14Gas valve control fault
- F15eBUS voltage failure
- F25Circulation fault
- F43General error
Potterton
- E119Low water pressure
- E133Gas supply interrupted
- E168General lockout
- E20Heating temperature sensor fault
- E28Flue sensor fault
- E40Return sensor fault
- E50Hot water sensor fault
- E110Overheat safety thermostat
- E118Water pressure too low
- E125Circulation fault
- E128Flame failure
- E130Flue thermostat tripped
- E135Gas supply interrupted
- E160Fan fault
- E321Hot water sensor fault
- E384False flame signal