Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Worcester Bosch fault code

Worcester Bosch A1: pump stuck or running dry

You can usually fix this

Checked against 2 sources ยท Updated November 2026

What it means

The pump is stuck or running with air instead of water, usually because the pressure is too low. HomeServe recommends checking the gauge and topping up to 1 bar.

Safe checks you can do

  1. Check the pressure gauge. Find the pressure gauge on the front or underneath the boiler. With the heating off and the boiler cold it should read roughly 1 to 1.5 bar. Anything under 1 bar is low. How to do this
  2. Top the pressure up if it's low. Open the filling loop slowly and watch the gauge. Stop at about 1.5 bar, close both valves fully, then reset the boiler. How to do this
  3. Bleed air out of the radiators. Radiators that are cold at the top have air in them. Bleed them with a radiator key, then check the pressure again, because bleeding lowers it. How to do this
  4. Reset the boiler, once or twice. Use the reset button or reset position on the dial, as your user manual shows. If the same code comes straight back after one or two resets, stop and book an engineer. How to do this

Common causes

  • Low water pressure
  • Air in the system
  • A seized pump

When to call an engineer

If the pressure is fine and A1 keeps returning, the pump may be seized and needs an engineer.

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).

Can I fix Worcester Bosch A1 myself?

Usually, yes. It's normally something you can sort yourself with the checks on this page.

How to reset a Worcester Bosch boiler

Press the reset button (marked with a circular arrow or the word reset) and hold it for a few seconds until the display changes. Only reset once or twice. A code that keeps returning is the boiler telling you something needs fixing.

Sources

We checked this code against the following, last reviewed November 2026. Codes can vary slightly between models, so your boiler's own manual is the final word.