F1 boiler fault: what it means

Short answer

F1 means different things on different brands. On Ideal boilers, the most common place you'll see it, F1 means low water pressure.

Boiler codes aren't standard across manufacturers, so check the brand name on the front of your boiler. Here's what F1 means on each brand that uses it:

F1

On a Ideal boiler: low water pressure

The boiler has stopped because the water pressure is low. Ideal says to check the gauge reads between 1 and 1.5 bar and repressurise if it doesn't.

You can usually fix this

Full Ideal F1 guide and fixes

On some older Glow-worm models F1 indicated an ignition problem. Current Glow-worm boilers use codes with a dot, such as F.28.

First things to check

  1. Check the pressure gauge. Find the pressure gauge on the front or underneath the boiler. With the heating off and the boiler cold it should read roughly 1 to 1.5 bar. Anything under 1 bar is low. How to do this
  2. Top the pressure up if it's low. Open the filling loop slowly and watch the gauge. Stop at about 1.5 bar, close both valves fully, then reset the boiler. How to do this
  3. Reset the boiler, once or twice. Use the reset button or reset position on the dial, as your user manual shows. If the same code comes straight back after one or two resets, stop and book an engineer. How to do this

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).

Look up a different code