Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Brand guide

Glow-worm boiler fault codes

Glow-worm is part of the Vaillant Group, and its current boilers use the same F codes as Vaillant, such as F.22 and F.28. Older Glow-worm models used different codes, so check the manual if your boiler is more than about 15 years old.

Covers: Energy, Ultimate, Betacom and Easicom ranges.

CodeWhat it meansCan you fix it?
F.22 Low water pressureUsually DIY
F.28 Failed to light on start-upCheck first
F.29 Flame lost during operationCheck first
F.75 Pressure sensor or pump faultCheck first
F.20 Overheat safety cut-outCheck first
F.23 Water not circulating wellCheck first
F.24 Temperature rising too fastCheck first
F.26 Gas valve faultEngineer
F.27 Flame detected when there shouldn't be oneEngineer
F.32 Fan faultEngineer
F.49 eBUS voltage faultCheck first
F.54 No gas pressure on start-upCheck first
F.61 Gas valve control faultEngineer
F.62 Gas valve slow to shut offEngineer
F.63 Memory fault on the circuit boardEngineer
F.64 Electronics or sensor faultEngineer
F.65 Electronics overheatingEngineer
F.67 Implausible flame signalEngineer
F.68 Unstable flame signalCheck first
F.70 Software or device number mismatchEngineer
F.72 Temperature sensor mismatchEngineer
F.73 Pressure sensor signal too lowCheck first
F.74 Pressure sensor signal too highCheck first
F.77 Condensate pump faultEngineer
F.83 Temperature not rising as expectedCheck first
F.84 Temperature sensors disagreeEngineer
F.85 Underfloor or sensor contact faultEngineer
F1 Ignition faultCheck first
F3 Fan not reaching ignition speedEngineer
F4 Ignition faultCheck first
F5 OverheatingCheck first
F6 Heating flow thermistor faultEngineer
F9 Pressure sensor, flow filter or pump faultCheck first
F10 Heating return thermistor faultEngineer
F11 Main board connection faultEngineer
F13 Circuit board memory faultEngineer
F14 Gas valve control faultEngineer
F15 eBUS voltage failureCheck first
F25 Circulation faultCheck first
F43 General errorEngineer

Resetting a Glow-worm boiler

Press the reset button (the circular arrow) once. If the code returns straight away, don't keep resetting.

Before you call anyone

Most Glow-worm faults we see searched for come down to three things: low water pressure, no gas reaching the boiler, or a frozen condensate pipe in winter. Check all three first.