EA 227
Fault code, any brand
227 boiler fault: what it means
Short answer
227 is the cause code shown with EA on Worcester Bosch boilers. EA 227 means no flame was detected after the boiler tried to light.
Boiler codes aren't standard across manufacturers, so check the brand name on the front of your boiler. Here's what 227 means on each brand that uses it:
EA 227
On a Worcester Bosch boiler: no flame detected after ignition
The boiler tried to light several times and didn't detect a flame. HomeServe notes Worcester boilers make four ignition attempts, with a pause between each, before locking out with EA 227.
Try the checks, then call an engineerFirst things to check
- Check you have gas. Try the hob or another gas appliance. If nothing works, check the lever on the gas meter is in line with the pipe (that means on) and, on a prepayment meter, that you have credit.
- Check the condensate pipe in freezing weather. The plastic pipe that runs from the boiler to an outside drain can freeze when it's below zero. Thaw it with a hot water bottle or warm water from a watering can, never boiling water, then reset. How to do this
- Reset the boiler, once or twice. Use the reset button or reset position on the dial, as your user manual shows. If the same code comes straight back after one or two resets, stop and book an engineer. How to do this
Need an engineer?
For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).