Baxi fault code
Baxi H.02.06: low pressure warning
You can usually fix thisChecked against 2 sources ยท Updated November 2026
On Baxi 200 and 400 combis, the system pressure is low, or there's a leak in the boiler or system.
Safe checks you can do
- Check the pressure gauge. Find the pressure gauge on the front or underneath the boiler. With the heating off and the boiler cold it should read roughly 1 to 1.5 bar. Anything under 1 bar is low. How to do this
- Top the pressure up if it's low. Open the filling loop slowly and watch the gauge. Stop at about 1.5 bar, close both valves fully, then reset the boiler. How to do this
- Reset the boiler, once or twice. Use the reset button or reset position on the dial, as your user manual shows. If the same code comes straight back after one or two resets, stop and book an engineer. How to do this
Common causes
- Pressure has dropped naturally over time
- Radiators have recently been bled
- A leak in the pipes, radiators or boiler
- The pressure relief valve letting water out
When to call an engineer
If you're topping up more than every few months, there's a leak and an engineer should find it.
Need an engineer?
For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).
Can I fix Baxi H.02.06 myself?
Usually, yes. It's normally something you can sort yourself with the checks on this page.
How to reset a Baxi boiler
Press and hold the reset button for one to three seconds, or until the boiler restarts. On older dial models, turn the selector to reset and hold it for about five seconds. Only reset once or twice. A code that keeps returning is the boiler telling you something needs fixing.