Vaillant boiler fault codes

Vaillant boilers show codes as an F, a dot and a number, for example F.28. The F stands for fault. Most homeowner-fixable Vaillant codes come down to low water pressure or a gas supply problem.

Covers: ecoTEC plus, ecoTEC pro, ecoFIT pure and other current ranges.

CodeWhat it meansCan you fix it?
F.22 Low water pressureUsually DIY
F.28 Boiler failed to light on start-upCheck first
F.29 Flame went out and wouldn't relightCheck first
F.75 Pump didn't detect a pressure riseCheck first
F.83 Temperature not rising as expectedCheck first
F.20 Overheat safety cut-outCheck first
F.23 Water not circulating wellCheck first
F.24 Temperature rising too fastCheck first
F.25 Flue gas temperature too highEngineer
F.27 Flame detected when there shouldn't be oneEngineer
F.32 Fan faultEngineer
F.54 No gas pressure on start-upCheck first
F.61 Gas valve control faultEngineer
F.62 Gas valve slow to shut offEngineer
F.72 Temperature sensor mismatchEngineer
F.00 Flow temperature sensor disconnectedEngineer
F.01 Return temperature sensor disconnectedEngineer
F.02 Hot water outlet sensor disconnectedEngineer
F.03 Cylinder temperature sensor disconnectedEngineer
F.10 Flow temperature sensor short circuitEngineer
F.11 Return temperature sensor short circuitEngineer
F.12 Hot water outlet sensor short circuitEngineer
F.13 Cylinder or warm-start sensor short circuitEngineer
F.26 Gas valve not workingEngineer
F.42 Coding resistor faultEngineer
F.49 eBUS voltage too lowCheck first
F.52 Mass flow sensor not connectedEngineer
F.53 Unexpected gas flow through the valveEngineer
F.55 Carbon monoxide sensor faultEngineer
F.56 Carbon monoxide limit exceededEngineer
F.57 Fault in the measuring programmeEngineer
F.63 EEPROM memory faultEngineer
F.64 Electronics or safety sensor faultEngineer
F.65 Electronics overheatingEngineer
F.67 Implausible flame signalEngineer
F.68 Unstable flame signalCheck first
F.70 Invalid device numberEngineer
F.71 Flow sensor reading implausibleEngineer
F.73 Pressure sensor signal too lowCheck first
F.74 Pressure sensor signal too highCheck first
F.77 Flue flap or condensate pump faultEngineer
F.78 External control wiring faultEngineer
F.80 Store inlet sensor faultEngineer
F.81 Cylinder charging pump faultEngineer
F.82 Cylinder anode faultEngineer
F.84 Temperature difference implausibleEngineer
F.85 Temperature sensors fitted wronglyEngineer
F.90 Store communication faultEngineer
F.91 Store sensor faultEngineer
F.92 Wrong gas typeEngineer
F.93 Combustion out of rangeEngineer
F.94 Pressure sensors implausibleEngineer

Resetting a Vaillant boiler

On most Vaillant models press the reset button (the circular arrow) once. Some ranges reset from the menu.

Before you call anyone

Most Vaillant faults we see searched for come down to three things: low water pressure, no gas reaching the boiler, or a frozen condensate pipe in winter. Check all three first.