What should my boiler pressure be?

Quick answer

About 1 to 1.5 bar with the heating off and the boiler cold. When the heating is running it can climb towards 2 bar, which is normal. Below 1 bar is too low, and above about 2.5 bar is too high.

Check your reading

01234
Normal when cold: about 1 to 1.5 bar. It can rise to around 2 bar when the heating is on.
Is the heating on?

Too low (under 1 bar)

Low pressure is the most common reason a combi or system boiler stops working. Many brands show a fault code for it: F1 on Ideal, F.22 on Vaillant and Glow-worm, E119 on Baxi and Potterton, and A1 on some Worcester Bosch boilers. You can usually top it up yourself in a few minutes.

How to top up boiler pressure

Too high (over 2.5 bar)

High pressure usually means too much water went in when it was last topped up, or the filling loop has been left slightly open. Most domestic boilers have a pressure relief valve that opens at 3 bar and lets water out through a small pipe outside.

How to reduce boiler pressure

Keeps dropping?

A boiler that needs topping up more than every few months has a leak somewhere. Check under radiators and the boiler for damp patches, and look for a dripping copper pipe on the outside wall. If you can't find it, an engineer can trace it.

Which type of boiler has a gauge?

Combi and system boilers are sealed systems with a pressure gauge. Older regular (heat-only) boilers with a tank in the loft are usually open-vented and don't have one, so pressure isn't something you need to manage.

Need it fixed?

Get a Gas Safe engineer to call you back about your boiler, or cover future breakdowns with a monthly plan.