Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Fault code, any brand

F75 boiler fault: what it means

Short answer

F75 (shown as F.75) means the boiler didn't detect a pressure rise when the pump started. It appears on Vaillant and Glow-worm boilers and usually points to low pressure, air, the pump or the pressure sensor.

Boiler codes aren't standard across manufacturers, so check the brand name on the front of your boiler. Here's what F75 means on each brand that uses it:

F.75

On a Vaillant boiler: pump didn't detect a pressure rise

When the pump starts, the boiler expects the water pressure to jump slightly. With F.75 it didn't see that jump. Vaillant's manual calls this a pump or water shortage fault.

Try the checks, then call an engineer

Full Vaillant F.75 guide and fixes

F.75

On a Glow-worm boiler: pressure sensor or pump fault

The boiler didn't detect the pressure change it expects when the pump starts. It points to low pressure, air, the pump or the pressure sensor.

Try the checks, then call an engineer

Full Glow-worm F.75 guide and fixes

First things to check

  1. Check the pressure gauge. Find the pressure gauge on the front or underneath the boiler. With the heating off and the boiler cold it should read roughly 1 to 1.5 bar. Anything under 1 bar is low. How to do this
  2. Top the pressure up if it's low. Open the filling loop slowly and watch the gauge. Stop at about 1.5 bar, close both valves fully, then reset the boiler. How to do this
  3. Bleed air out of the radiators. Radiators that are cold at the top have air in them. Bleed them with a radiator key, then check the pressure again, because bleeding lowers it. How to do this
  4. Reset the boiler, once or twice. Use the reset button or reset position on the dial, as your user manual shows. If the same code comes straight back after one or two resets, stop and book an engineer. How to do this

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).

Look up a different code