Smell gas? Leave the property and call the National Gas Emergency Service on 0800 111 999, 24 hours.

Baxi fault code

Baxi E.01.20: flue gas too hot

Needs a Gas Safe engineer

Checked against 2 sources · Updated November 2026

What it means

On Baxi 200 and 400 combis, the flue gas went over 140°C.

Safe checks you can do

  1. Look at the flue from outside. Check the flue terminal on the outside wall or roof isn't blocked by leaves, a nest, snow or something stacked in front of it. Don't touch, cover or take apart the flue itself.
  2. Check the condensate pipe in freezing weather. The plastic pipe that runs from the boiler to an outside drain can freeze when it's below zero. Thaw it with a hot water bottle or warm water from a watering can, never boiling water, then reset. How to do this

Common causes

  • A blocked flue terminal outside
  • A frozen or blocked condensate pipe
  • A faulty flue sensor or thermostat

When to call an engineer

Flue faults affect how exhaust gases leave your home. Don't keep resetting. Book a Gas Safe engineer.

Need an engineer?

For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).

Can I fix Baxi E.01.20 myself?

No. Apart from the simple outside checks here, this needs a Gas Safe registered engineer.

How to reset a Baxi boiler

Press and hold the reset button for one to three seconds, or until the boiler restarts. On older dial models, turn the selector to reset and hold it for about five seconds. Only reset once or twice. A code that keeps returning is the boiler telling you something needs fixing.

Sources

We checked this code against the following, last reviewed November 2026. Codes can vary slightly between models, so your boiler's own manual is the final word.