How to top up boiler pressure
Quick answer
Turn the boiler off and let it cool, then slowly open the filling loop valves and watch the gauge. Close them when it reads about 1.5 bar, and turn the boiler back on.
- Turn the boiler off and let it cool. Pressure reads higher when the system is hot, so you'll get the wrong reading if you top up while it's warm.
- Find the filling loop. It's usually a silver braided hose with a valve at each end, underneath the boiler. Some boilers, including several Worcester Bosch models, use a removable key instead, and some Baxi models have two wheel valves.
- Check both ends are attached. If the hose has been removed, reconnect it hand-tight.
- Open the valves slowly. Turn the first valve so the handle lines up with the pipe, then open the second. You'll hear water flowing in.
- Watch the gauge. Stop when it reaches about 1.5 bar. Don't overfill.
- Close both valves fully. A valve left slightly open is a common reason for pressure creeping too high later.
- Turn the boiler back on and reset it if it's still showing a fault code.
If water drips when you disconnect the hose afterwards, have a towel ready. A small drip is normal.
How often should I need to do this?
Once or twice a year is normal, especially after bleeding radiators. If you're doing it every few weeks, there's a leak, and an engineer should find it before it damages anything.
Need an engineer?
For anything beyond the safe checks on this page, use a Gas Safe registered engineer. Find one near you, or check an engineer's ID, on the official Gas Safe Register (free helpline 0800 408 5500).